Contact us | +1 973.345.5885 |

30 Watt

Single and Dual Output


Efficient AC-DC power supplies with short circuit protection

Our UIL30 series of AC-DC converters feature an internal input filter, high efficiency up to 88% and a universal input of 90 to 264 Vac. This series also features dimensions of 3.5" x 2.5" x 1.25", as well as short circuit, overload and over voltage protection.

UIL 30

 

INPUT

  • Voltage Range
    • Vo, lo nom, AC input: 90 - 264 Vac
    • Vo, lo nom, DC input: 120 - 370 Vac
  • Rated Input Voltage
    • Vo, lo nom: 100 - 240 Vac
  • Line Frequency
    • Vi nom, lo nom: 47 - 63 Hz
  • Inrush Current
    • lo nom, Vi: 115 Vac, 12 A
    • lo nom, Vi: 230 Vac, 20 A
  • Input fuse
    • VDE/UL/CCC, Fuse 2.5A/250V (slow blow)

OUTPUT

  • Output voltage accuracy
    • Vi nom, lo nom, single output, 3.3 - 9V models: ±3%
    • Vi nom, lo nom, single output, 10 - 48V models: ±2%
    • Dual output: ±5%
  • Minimum load
    • Vi nom, single output models: 0% min
    • Vi nom, dual output models: 20% min
  • Line regulation
    • Lo nom, Vi min, Vi max: ±1%
  • Load regulation
    • Lo min- lo nom, single output models: ±2%
    • Lo min- lo nom, dual output models: ±5%
  • Transient recovery time: 1,000 uS
  • Overload protection
    • Above 110% rated output power
    • Recovers automatically after fault condition is removed
  • Short circuit protection
    • Recovers automatically after fault condition is removed
  • Over voltage protection (main output)
    • 120 - 150% rated output voltage
    • Zener diode clamp

GENERAL

  • Isolation voltage
    • Input to output: 3KVac/5mA/5secs
  • Isolation resistance
    • Input to output: 500 Vdc, 100 MΩ
  • Switching frequency
    • Vi nom, lo nom: 65 kHz

ENVIRONMENTAL

  • Operating temperature: -20 to 70°C
  • Derating
    • Vi nom, lo nom: 51 to 71°C
  • Storage temperature
    • Non-operational: -40 to 85°C
  • Relative humidity
    • Ni nom, lo nom: 95% RH
  • Cooling: Free air convection

PHYSICAL

  • Design meets safety standard: EN60950-1
  • Dimensions: 3.5 x 2.5 x 1.25 mm

EMC Characteristics

  • EMI conduction and radiation: compliant to EN55022
  • EMS immunity: compliant to EN55024
Output Wattage (W) Output Voltage
(Vdc)
Output Current
Max. Load (mA)
Ripple and Noise
mV (Max.)
Efficiency (%) Model Number
26.4 3.3 8000 150 72 UIL30-33S
40 5 8000 150 75 UIL30-5S
6 6650 150 75 UIL30-6S
7 5700 150 80 UIL30-7S
8 5000 150 80 UIL30-8S
9 4400 150 82 UIL30-9S
10 4000 150 82 UIL30-10S
42 12 3500 150 84 UIL30-12S
13 3200 150 84 UIL30-13S
14 3000 150 84 UIL30-14S
15 2800 150 84 UIL30-15S
16 2625 150 85 UIL30-16S
18 2300 150 85 UIL30-18S
24 1750 240 86 UIL30-24S
27 1550 240 86 UIL30-27S
43.2 36 1200 240 86 UIL30-36S
48 48 1000 240 88 UIL30-48S
Dual Output
26.5 33/50 2 1/2 5/8 72 UIL30-33S5S
40 ±5 ±4000 150 75 UIL30-05D
5/12- 4 5/8 75 UIL30-5S12S
5/15- 5 5/8 75 UIL30-5S15S
5/24- 8 5/8 78 UIL30-5S24S
42 ±12 ±1750 150 80 UIL30-12D
±15 ±1400 150 80 UIL30-15D
±24 ±875 240 80 UIL30-24D