65 Watt
Universal Input Range
AC-DC converters meet medical safety approvals
With a universal input range and high efficiency up to 92%, our 65-watt MUI65 series of AC-DC converters for medical applications has an operating temperature range of -25 to 80°C, low leakage current under 75µA and a built-in EMI class A filter. This model also features an operating altitude of 5000M, 0.11 watt low standby power consumption and a 2000 VAC input to output 2 MOPP isolation. In addition, this model meets all UL, CE and ANSI/AAMI ES60602-2, EN60601-1 and IEC60601-1 safety standards.

INPUT
- Voltage Range
- AC input: 85 - 264 Vac
- DC input: 120 - 370 Vdc
- Input frequency
- AC input: 47 - 63 Hz
- Input current
- 100 Vac and full load: 1.6 A
- 240 Vac and full load: 0.9 A
- No load input power
- 230 Vac: 0.11 watts
- Leakage current
- 264 Vac: 75µA
- Start-up time: 1000 ms
- Rise time: 20 ms
- Hold-up time
- 115 Vac and full load: 16 ms
- Input inrush current
- 230 Vac: 60 A
- Input protection
- Internal fuse in line and neutral: T3.15A/250Vac
OUTPUT
- Output power: 65 Watts
- Initial set voltage
- 230 Vac and full load: ±1%
- Line regulation
- Low line to high line at full load: ±0.2%
- Load regulation
- No load to full load, 5Vout: ±0.7%
- Output voltages: ±0.5%
- 10% load to 90% load, 5Vout: ±0.6%
- 10% load to 90% load, others: ±0.4%
- Voltage adjustability
- Single output, 53Vout: -20 - 10%
- Single output, others: ±10%
- Minimum load: 0%
- Ripple and noise (measured by 20 MHz bandwidth)
- With a 10µF/25V 1206 X7R MLCC, 5Vout, 7.5Vout, 9Vout, 12Vout, 15Vout: 75 mVp-p
- With a 1µF/50V 1206 X7R MLCC, 24Vout, 28Vout, 36Vout: 75 mVp-p
- With a 0.1µF/100V 1206 X7R MLCC, 48Vout, 53Vout: 150 mVp-p
- Temperature coefficient: ±0.02%/°C
- Transient response peak deviation
- Load step change from 50-75% at 2.5A/µs: 3Vout
- Transient response recovery time: 600µs
- Over voltage protection
- % of Vout(nom); latch mode: 125 - 140%
- Over load protection
- % of lout rated; hiccup mode: 145%
- Short circuit protection: continuous, automatic recovery
GENERAL SPECIFICATIONS
- Isolation voltage (1 min, 2 MOPP isolation)
- Input to Output: 4000 Vac
- Input (output) to FG: 2500 Vac
- Isolation resistance: 500 Vdc: 0.1 GΩ
- Switching frequency
- 5Vout: 230 Vac, 60 kHz
- 7.5Vout: 80 kHz
- 9Vout: 70 kHz
- Others: 120 kHz
ENVIRONMENTAL SPECIFICATIONS
- Operating ambient temperature
- Natural convection with derating: -40 - 80°C
- Storage temperature range: -40 - 85°C
- Operating altitude
- Vertical direction by natural convection (20LFM): 5000 m
- Shock: IEC60068-2-27
- Vibration: IEC60068-2-6
- Relative humidity
- Non-condensing: 5 to 95% RH
PHYSICAL SPECIFICATIONS
- Design meet safety standard
- ANSI/AAMI, ES60601-1, IEC60601-1, EN60601-1
- Weight
- MUIO: 117g (4.13oz)
- MUIT: 157g (5.54oz)
- MUI: 172g (6.07oz)
- MUID: 193 (6.81oz)
- Dimensions: 2.00" x 3.00" x 1.16" (50.8mm x 76.2mm x 29.46mm)
- MTBF: 1.494 x 10^6 hrs, MIL-HDBK-217F, full load
EMC SPECIFICATIONS
- EMI
- EN55011, EN55022 and FCC Part 18
- Conducted: Class B
- Radiated: Class B
- EN55011, EN55022 and FCC Part 18
- Harmonic currents
- EN6100-3-2, full load: Class A
- Voltage flicker: EN61000-3-3
- ESD
- EN61000-4-2, Perf. Criteria A
- Air ±8KV and Contact ±6KV
- EN61000-4-2, Perf. Criteria A
- Radiated immunity
- EN61000-4-3, Perf. Criteria A: 20 V/m
- Fast transient
- EN61000-4-4, Perf. Criteria A: ±2KV
- Surge
- EN61000-4-5, Perf. Criteria A
- DM ±1KV and CM ±2KV
- EN61000-4-5, Perf. Criteria A
- Conducted immunity
- EN61000-4-6, Perf. Criteria A: 20 Vr.m.s
- Power frequency magnetic field
- EN6100-4-8, Perf. Criteria A: 10 A/M
- Dip and interruptions
- EN60601-1-2
- 230 Vac 50Hz, 30%, 500mS, Perf. Criteria A
- 230 Vac, 50Hz, 60%, 100mS, Perf. Criteria A
- 230 Vac, 50Hz, >95%, 10mS, Perf. Criteria A
- 230 Vac, 50Hz, >95%, 5000mS, Perf. Criteria B
- EN61000-4-11
- 100 Vac, 50Hz, 30%, 500mS, Perf. Criteria A
- 100 Vac, 50Hz, 60%, 100mS, Perf. Criteria B
- 100 Vac, 50Hz, >95%, 10 mS, Perf. Criteria A
- 100 Vac, 50Hz, >95%, 5000mS, Perf. Criteria B
- EN60601-1-2
Input Range Vac | Output Voltage Vdc |
Output Current at Convention Cooled 60ºC TA A |
Max. Output Power W |
Input Power at No Load W |
Efficiency (%) | Model Number |
85-264 | 5 | 10 | 50 | 0.11 | 90 | MUI65-5SB |
7.5 | 8.67 | 65 | 0.11 | 90 | MUI65-7SB | |
9 | 7.23 | 65 | 0.11 | 91 | MUI65-9SB | |
12 | 5.42 | 65 | 0.11 | 92.5 | MUI65-12SB | |
15 | 4.34 | 65 | 0.11 | 93.5 | MUI65-15SB | |
24 | 2.71 | 65 | 0.11 | 93.5 | MUI65-24SHB | |
24 | 2.71 | 65 | 0.11 | 92 | MUI65-24SB | |
28 | 2.33 | 65 | 0.11 | 93.5 | MUI65-28SHB | |
28 | 2.33 | 65 | 0.11 | 91.5 | MUI65-28SB | |
36 | 1.81 | 65 | 0.11 | 92.5 | MUI65-36SB | |
48 | 1.36 | 65 | 0.11 | 93 | MUI65-48SB | |
53 | 1.24 | 65 | 0.11 | 92.5 | MUI65-53SB |