150 Watt
Universal Input, 2” x 4” x 1.16” Package
AC-DC Converters For Industrial Applications
These 150-watt AC-DC converters are ideal for industrial applications. The UI150 is housed in a 2” x 4” x 1.16” package and offer 85 V to 264 V ac universal input, adjustable output voltages as high as 48 Vdc, efficiency up to 92%, low standby power for energy savings, low leakage current and an internal filter to EN55032 Class B standards. These Protection Class I and Class II devices provide 3000 Vac reinforced insulation, and they meet IEC/UL/EN60950-1. Safeguards also include over current, over voltage and short circuit protections. The operating altitude is 5000 m. UI150 AC-DC converters meet safety certifications including IEC/UL/EN60950-1, carry the CE Mark and comply to the RoHS and REACH requirements.

INPUT
- Operating Input Voltage Range:
- AC input, VAC: 85 Min., 264 Max. Vac
- DC input, VDC: 120 Min., 370 Max. Vdc
- Input Frequency: AC input, 47 Min., 63 Max. Hz
- Input Current:
- 115VAC and full load, 1.7 Max. A
- 230VAC and full load, 0.8 Max. A
- No Load Input Power:
- 230VAC, Option -F (with fan), 0.6 Typ. Watts
- 230VAC, Others, 0.3 Max. Watts
- Leakage Current: 264VAC, 300 Max. μA
- Power Factor: 0.95 Min.
- Start Up Time: 1000 Max. ms
- Rise Time: 20 Typ. ms
- Hold Up Time: 115VAC and full load, 16 Min. ms
- Input Inrush Current: 230VAC, 100 Max. A
- Input Protection: Internal fuse, T3.15A/250VAC
OUTPUT
- Output Power: 100 Max. Watts
- Forced air cooling with 10CFM or Option -F, 150 Max. Watts
- Natural convection for 15Vout, 24Vout, 28Vout, 36Vout, 110 Max. Watts
- Natural convection for 12Vout, 48Vout, 100 Max. Watts
- Initial Set Voltage Accuracy: 230VAC and Full load, -1 Min., 1 Max. %
- Line Regulation: Low Line to High Line at Full Load, -0.2 Min., 0.2 Max. %
- Load Regulation:
- No load to full load, -0.5 Min., 0.5 Max. %
- 10% load to 90% load, -0.4 Min., 0.4 Max. %
- Voltage Adjustability: -10 Min., 10 Max. %
- Minimum Load: 0 Typ. %
- Ripple and Noise
- Measured by 20MHz bandwidth
- With a 10μF/25V 1206 X7R MLCC, 12Vout, 120 Typ. mVp-p
- With a 10μF/25V 1206 X7R MLCC, 15Vout, 150 Typ. mVp-p
- With a 1μF/50V 1206 X7R MLCC, 24Vout, 220 Typ. mVp-p
- With a 1μF/50V 1206 X7R MLCC, 28Vout, 220 Typ. mVp-p
- With a 1μF/50V 1206 X7R MLCC, 36Vout, 250 Typ. mVp-p
- With a 0.1μF/100V 1206 X7R MLCC, 48Vout, 250 Typ. mVp-p
- Temperature Coefficient: ±0.02%/°C Max.
- Transient Response Recovery Time:
- Load step from 50-75% change at 2.5A/μs
- Peak deviation, 3 Max. %Vout
- Recovery time, 500 Typ. μs
- Over Voltage Protection: % of Vout(nom); Latch mode, 115 Min., 135 Max. %
- Over Load Protection: % of lout rated; Hiccup mode, 115 Min., 150 Max. %
- Short Circuit Protection: Continuous, automatic recovery
- Fan Power Supply: 12V at 500mA
GENERAL SPECIFICATIONS
- Isolation Voltage
- 1 minute (reinforced insulation), Input to output, 3000 Min. Vac
- Input (output) to F.G., 1500 Min. Vac
- Isolation Resistance: 0.1 Min. GΩ, 500Vdc
- Isolation Capacitance: 2000 pF, Max.
- Switching Frequency: 60 Typ. kHz
ENVIRONMENTAL SPECIFICATIONS
- Operating Ambient Temperature
- Option -F (with fan), With derating, -40 Min., 80 Max. ºC
- Others, -40 Min., 85 Max. ºC
- -40ºC start up: 80% load, Max., at Vin > 100VAC
- -40ºC start up: 100% load, Max., at Vin > 200VAC
- Storage Temperature Range:
- Option -F (with fan), -40 Min., 75 Max. ºC
- Others, -40 Min., 85 Max. ºC
- Operating Altitude: 5000 Max. m
- Thermal Shock: MIL-STD-810F
- Shock: IEC60068-2-27
- Vibration: IEC60068-2-6
- Relative Humidity: Non-condensing, 5% to 95% RH
PHYSICAL SPECIFICATIONS
- Design Meet Safety Standard: IEC/UL/EN60950-1, UL:E193009, CB: DK-56637-UL
- Weight:
- UI: 187g (6.60oz)
- UIO: 235g (8.29oz)
- UIOU: 256g (9.03oz)
- UIOD: 278g (9.81oz)
- Dimensions: 2” × 4” × 1.16” (50.8mm × 101.6mm × 29.5mm)
- MTBF: 7.861 × 105 hrs, MIL-HDBK-217F Ta=25oC, Full load
EMC SPECIFICATIONS
- EMI: EN55024, EN55011, EN55022 and FCC Part 15, External components may be required for class I application, Conducted, Class B Radiated, Class A
- Harmonic Currents: EN61000-3-2, Full load, Class A and D
- Voltage Flicker: EN61000-3-3
- EMS: EN55024
- ESD: EN61000-4-2, Air ±8kV and Contact ±6kV, Perf. Criteria A
- Radiated Immunity: EN61000-4-3, 20V/m, Perf. Criteria A
- Fast Transient: EN61000-4-4, ±2KV, Perf. Criteria A
- Surge: EN61000-4-5, DM ±1KV and CM ±2KV, Perf. Criteria A
- Conducted Immunity: EN61000-4-6, 20 Vr.m.s, Perf. Criteria A
- Power Frequency Magnetic Field: EN61000-4-8, 10 A/m, Perf. Criteria A
- Dip and Interruptions: EN61000-4-11
Input Range (Vac) |
Output Voltage (Vdc) |
Output Current Natural Convection Open Type and Chasses Type (A) |
Output Current Natural Convection Enclosed Type and Din RailType (A) |
Output Current Forced Air Cooling with 10CFM/Option with Fan (A) |
Efficiency (%) |
Model Number | |
---|---|---|---|---|---|---|---|
Single Output | |||||||
85 - 264 | 12 | 8.34 | 10.84 | 12.5 | 91 | UI150-12S | |
85 - 264 | 15 | 7.34 | 9 | 10 | 92 | UI150-15S | |
85 - 264 | 24 | 4.59 | 5.63 | 6.25 | 92 | UI150-24S | |
85 - 264 | 28 | 3.93 | 4.83 | 5.36 | 92 | UI150-28S | |
85 - 264 | 36 | 3.06 | 3.75 | 4.17 | 92 | UI150-36S | |
85 - 264 | 48 | 2.09 | 2.71 | 3.13 | 92 | UI150-48S |